mT-Jump - Rapid Mixing Temperature Jump System

· Hot and cold jumps
· T-changes as high as several ten of degrees
· Low volume consumption
· Millisecond resolution

Principle
This new T-jump instrument achieves temperature changes by mixing two solutions of different initial temperatures T1 and T2. The final temperature of the mixture (T3) is calculated from the initial temperatures T1 and T2 and the mixing ratio of the two solutions.

Three thermoelectric Peltier elements are used to control the initial temperatures of the two solutions and that of the observation cell after mixing. The mT-jump accessory is installed on a Bio-Logic stopped-flow basis.

The system is fully controlled from the Bio-Kine32 software: the user defines the mixing ratio for the reaction and the amplitude of the temperature jump.
The temperature of each Peltier element is then automatically adjusted. Automatic accumulation of shots is possible to optimize the signal to noise ratio.

The mT-jump system is equipped with a standard Bio-Logic stopped-flow observation cell. It is compatible with all modes of observations such as circular dichroism, fluorescence, absorbance, and fluorescence anisotropy.

A complementary instrument to classical T-jump

The aim of classical T-jump instruments is to record fast heat induced relaxations of reactions. This is normally achieved by applying fast electric current pulses or more recently infrared laser pulses to the sample. Time resolution of classical T-jump can reach a few μs but the kinetics cannot be recorded for more than a few ms due to temperature dissipation, which could be a limitation in some applications. Most classical temperature jump devices are limited to 5°C and are unable to perform cooling jumps.

Bio-Logic’s mT-jump is based on Stopped-Flow technology and thus offers millisecond resolution. The amplitude of the jump is entirely controlled by the user (up to 40°C jump) and the jump can be in both directions (cooling or heating jump) which offers new investigation domains, for example: refolding studies. Protein folding and refolding can easily be studied without adding denaturant to the protein! Detection with classical T-jump instrumentation is also limited to techniques such as absorbance and fluorescence whereas mT-jump is compatible with all optical methods (including circular dichroism, FT-IR, fluorescence anisotropy…)

Specifications

Temperature control specifications
? Full software control through USB connection.
? Temperature range : +5°C / +90°C
? Precision of temperature reading: 0.01°C
? Maximum temperature jump : +/- 40°C
? Temperature stability for S1 and S2 in stationary state: < +/- 0.2°C at 80°C after 15 minutes of equilibrium.
? Temperature stability in the cuvette after the T-jump: variation < 1% per 30s
? Precision of the T-jump: defined by user calibration (down to +/- 0.1°C)
? Temperature probe is included.

Mixing specifications
? Compatible with all SFM.
? Mixing Ratio from 1/1 to 1/4.
? Sample consumption per shot : 45 μl to 220 μl.
? Dead time: depends on cuvette, stopped-flow model and mixing ratio (0.7ms using SFM-2000 series and FC-08 cuvette)
? compatible with MOS-200, MOS-450/AF-CD, Diode Array detector and external devices.
? optional FT-IR cell.

Copyright Dalian Huayang analytical instruments Co., Ltd.All right reserved. Preparation of Liao ICP
友情鏈接: link1 link2 link3 link4 link5 link8 link9
主站蜘蛛池模板: 97久久精品人人做人人爽 | 蕾丝视频在线看片国产 | 欧美一级特黄aa大片婷婷 | 亚洲 欧美 日韩 综合 | 亚洲欧美v | 美国一级毛片片aa免 | 日韩在线观看中文字幕 | 天堂中文在线资源 | 成年女人在线视频 | 黄色va视频 | 亚洲字幕在线观看 | 欧美黄色一级视频 | 欧美αv日韩αv另类综合 | 成人小视频免费观看 | 亚洲第一区精品观看 | 久久久久久久综合日本亚洲 | 欧美日韩精品在线 | 久久五十路 | 一本本久综合久久爱 | 99久久99久久免费精品蜜桃 | 三级网站在线 | 在线观看一夜七次郎国产 | 四虎国产精品永久免费网址 | 国产精品美乳在线观看 | 一本到不卡 | 99久久综合国产精品免费 | 色综合久久88色综合天天提莫 | 免费看全黄特黄毛片 | 性视频高清免费视频播放 | 精品福利一区 | 久久久久久99精品 | 欧美在线视频免费观看 | 爱爱日本| 2022欧美高清中文字幕在线看 | 成年人午夜免费视频 | 99热久久66是国产免费 | 亚洲午夜片| 国产精品亚洲一区二区三区正片 | 国产精品天天在线 | 手机看片福利国产 | 色日韩在线|