mT-Jump - Rapid Mixing Temperature Jump System

· Hot and cold jumps
· T-changes as high as several ten of degrees
· Low volume consumption
· Millisecond resolution

Principle
This new T-jump instrument achieves temperature changes by mixing two solutions of different initial temperatures T1 and T2. The final temperature of the mixture (T3) is calculated from the initial temperatures T1 and T2 and the mixing ratio of the two solutions.

Three thermoelectric Peltier elements are used to control the initial temperatures of the two solutions and that of the observation cell after mixing. The mT-jump accessory is installed on a Bio-Logic stopped-flow basis.

The system is fully controlled from the Bio-Kine32 software: the user defines the mixing ratio for the reaction and the amplitude of the temperature jump.
The temperature of each Peltier element is then automatically adjusted. Automatic accumulation of shots is possible to optimize the signal to noise ratio.

The mT-jump system is equipped with a standard Bio-Logic stopped-flow observation cell. It is compatible with all modes of observations such as circular dichroism, fluorescence, absorbance, and fluorescence anisotropy.

A complementary instrument to classical T-jump

The aim of classical T-jump instruments is to record fast heat induced relaxations of reactions. This is normally achieved by applying fast electric current pulses or more recently infrared laser pulses to the sample. Time resolution of classical T-jump can reach a few μs but the kinetics cannot be recorded for more than a few ms due to temperature dissipation, which could be a limitation in some applications. Most classical temperature jump devices are limited to 5°C and are unable to perform cooling jumps.

Bio-Logic’s mT-jump is based on Stopped-Flow technology and thus offers millisecond resolution. The amplitude of the jump is entirely controlled by the user (up to 40°C jump) and the jump can be in both directions (cooling or heating jump) which offers new investigation domains, for example: refolding studies. Protein folding and refolding can easily be studied without adding denaturant to the protein! Detection with classical T-jump instrumentation is also limited to techniques such as absorbance and fluorescence whereas mT-jump is compatible with all optical methods (including circular dichroism, FT-IR, fluorescence anisotropy…)

Specifications

Temperature control specifications
? Full software control through USB connection.
? Temperature range : +5°C / +90°C
? Precision of temperature reading: 0.01°C
? Maximum temperature jump : +/- 40°C
? Temperature stability for S1 and S2 in stationary state: < +/- 0.2°C at 80°C after 15 minutes of equilibrium.
? Temperature stability in the cuvette after the T-jump: variation < 1% per 30s
? Precision of the T-jump: defined by user calibration (down to +/- 0.1°C)
? Temperature probe is included.

Mixing specifications
? Compatible with all SFM.
? Mixing Ratio from 1/1 to 1/4.
? Sample consumption per shot : 45 μl to 220 μl.
? Dead time: depends on cuvette, stopped-flow model and mixing ratio (0.7ms using SFM-2000 series and FC-08 cuvette)
? compatible with MOS-200, MOS-450/AF-CD, Diode Array detector and external devices.
? optional FT-IR cell.

Copyright Dalian Huayang analytical instruments Co., Ltd.All right reserved. Preparation of Liao ICP
友情鏈接: link1 link2 link3 link4 link5 link8 link9
主站蜘蛛池模板: 国产younv真实 | 香蕉亚洲精品一区二区 | 青青草视频官网 | 边接电话边做国语高清对白 | 99国产精品一区二区 | 国产1区2区 | 成人免费看片 | 欧美在线视频一区 | 91成人免费观看 | 国产日韩高清一区二区三区 | 精品精品国产高清a毛片牛牛 | 青青操夜夜操 | 青青青国产在线观看免费网站 | 国产精品亚洲视频 | 天天摸夜夜操 | 日韩一级片在线播放 | 在线亚洲精品国产成人二区 | 国产成人亚洲精品一区二区在线看 | 成人牲交一极毛片 | 精品久久网站 | 高清不卡一区二区 | 99国产精品热久久久久久夜夜嗨 | 男女午夜性爽快免费视频不卡 | 麻豆视传媒一区二区三区 | 日本九色 | 国产成人精品无缓存在线播放 | 精品三级国产 | 爽爽影院免费观看视频 | 一本岛高清v不卡免费一三区 | 亚洲欧美色综合大色 | 亚洲精品高清在线一区二区三区 | 韩国三级在线观看我不卡 | 日日干综合 | 国产精品久久久久久久久鸭 | 国产成人91激情在线播放 | 狠狠r| 久久综合九色综合精品 | 男女免费爽爽爽在线视频 | 999视频精品全部免费观看 | 亚洲狠狠婷婷综合久久久久网站 | 2022国产福利在线观看 |