日韩成人在线视频-日韩成人在线网站-日韩成人综合网-日韩城人免费-日韩城人视频-日韩城人网站

Welcome to Dalian Huayang
Tel:400-901-3696

Search

  • Product
  • Brand
mT-Jump - Rapid Mixing Temperature Jump System

· Hot and cold jumps
· T-changes as high as several ten of degrees
· Low volume consumption
· Millisecond resolution

Principle
This new T-jump instrument achieves temperature changes by mixing two solutions of different initial temperatures T1 and T2. The final temperature of the mixture (T3) is calculated from the initial temperatures T1 and T2 and the mixing ratio of the two solutions.

Three thermoelectric Peltier elements are used to control the initial temperatures of the two solutions and that of the observation cell after mixing. The mT-jump accessory is installed on a Bio-Logic stopped-flow basis.

The system is fully controlled from the Bio-Kine32 software: the user defines the mixing ratio for the reaction and the amplitude of the temperature jump.
The temperature of each Peltier element is then automatically adjusted. Automatic accumulation of shots is possible to optimize the signal to noise ratio.

The mT-jump system is equipped with a standard Bio-Logic stopped-flow observation cell. It is compatible with all modes of observations such as circular dichroism, fluorescence, absorbance, and fluorescence anisotropy.

A complementary instrument to classical T-jump

The aim of classical T-jump instruments is to record fast heat induced relaxations of reactions. This is normally achieved by applying fast electric current pulses or more recently infrared laser pulses to the sample. Time resolution of classical T-jump can reach a few μs but the kinetics cannot be recorded for more than a few ms due to temperature dissipation, which could be a limitation in some applications. Most classical temperature jump devices are limited to 5°C and are unable to perform cooling jumps.

Bio-Logic’s mT-jump is based on Stopped-Flow technology and thus offers millisecond resolution. The amplitude of the jump is entirely controlled by the user (up to 40°C jump) and the jump can be in both directions (cooling or heating jump) which offers new investigation domains, for example: refolding studies. Protein folding and refolding can easily be studied without adding denaturant to the protein! Detection with classical T-jump instrumentation is also limited to techniques such as absorbance and fluorescence whereas mT-jump is compatible with all optical methods (including circular dichroism, FT-IR, fluorescence anisotropy…)

Specifications

Temperature control specifications
? Full software control through USB connection.
? Temperature range : +5°C / +90°C
? Precision of temperature reading: 0.01°C
? Maximum temperature jump : +/- 40°C
? Temperature stability for S1 and S2 in stationary state: < +/- 0.2°C at 80°C after 15 minutes of equilibrium.
? Temperature stability in the cuvette after the T-jump: variation < 1% per 30s
? Precision of the T-jump: defined by user calibration (down to +/- 0.1°C)
? Temperature probe is included.

Mixing specifications
? Compatible with all SFM.
? Mixing Ratio from 1/1 to 1/4.
? Sample consumption per shot : 45 μl to 220 μl.
? Dead time: depends on cuvette, stopped-flow model and mixing ratio (0.7ms using SFM-2000 series and FC-08 cuvette)
? compatible with MOS-200, MOS-450/AF-CD, Diode Array detector and external devices.
? optional FT-IR cell.

Copyright Dalian Huayang analytical instruments Co., Ltd.All right reserved. Preparation of Liao ICP
友情鏈接: link1 link2 link3 link4 link5 link8 link9
主站蜘蛛池模板: 亚洲在线视频观看 | 欧美精品h在线播放 | 久久久久一区二区三区 | 天堂资源在线官网资源 | 99re这里只有精品国产精品 | 美女被叉叉的影院 | 91亚洲国产成人精品性色 | 久草在线免费资源站 | 欧美国产精品 | 边操边吃奶 | 欧美太黄太色视频在线观看 | jlzz中国jizz日本老师水多 | 午夜无遮挡 | 经典欧美gifxxoo动态图暗网 | 色亚洲成人 | 久久中精品中文 | 欧美黄色高清 | 三级精品视频在线播放 | 久久综合综合久久97色 | 韩国理论片在线观看bd | 亚洲精品国产导航一区二区 | 久久艹综合 | 国产成人a∨麻豆精品 | 成年网站免费 | 久久亚洲伊人中字综合精品 | 国产成人免费高清视频 | 亚州不卡| 精品欧美在线观看 | 精品一区二区三区高清免费不卡 | 亚洲五级片| 免费人成在线观看网站 | 国产成人香蕉在线视频网站 | 欧美成人精品在线 | 久久天天躁夜夜躁狠狠躁2015 | 国产成人在线小视频 | 午夜精品成人毛片 | 国产精品白嫩在线观看 | 欧美午夜视频在线 | 欧美一级亚洲一级 | 天天综合色天天综合色sb | 国产亚洲精品xxx |